Troubleshooting
7. No Motor Function (FWD or REV)
No Motor Function (FWD or REV)
With the machine running, the water
valves on and the machine holding
water (i.e., filling up), the basket has
no wash function (i.e., FWD or REV).
4A
NO
YES
Is there voltage
(120 Volts AC) across
the coil of the KM3 and
the KM4 contactors?
Is there voltage
(120 Volts AC)
between wire FWD on the
output board and the ACN?
Is there voltage (120 Volts AC)
between wire REV on the
output board and
the ACN?
Is there voltage
(120 Volts AC)
between the input side of
the FWD fuse and the ACN?
Is there voltage (120 Volts AC)
between the input side
of the REV fuse and
the ACN?
NO
YES
Replace the output board.
NO
YES
1A
2A
2A
3A
Is there voltage
(120 Volts AC) between the
output side of the FWD fuse and
the ACN?
Is there voltage (120 Volts AC)
between the output side
of the REV fuse and
the ACN?
2A
3A
Replace the FWD and/or
the REV fuse as needed.
NO
Inspect the motor.
Repair/replace the motor
as needed.
YES
Inspect the contactors'
wiring connections.