Troubleshooting
10. Overflow Analysis
y
Water is running continuously into the machine.
2A
1A
Disconnect
power to the
machine. Does the
machine continue
to fill with
water?
NO
YES
NO
YES
3A
Repair/replace the water inlet valve that is
allowing water to enter the machine when
power is disconnected.
Reconnect
power to the machine.
Is the drain valve
closed tightly?
Refer to the "Drain Valve
Malfunction" flowchart.
NO
Make sure that the
water level switch is open.
Perform an ohms test
across terminals 21 and 24 on the
water level switch.
Is it opened or closed?
Perform an ohms test
across terminals 31 and 34
on the water level switch.
Is it opened or
closed?
YES
YES
Examine the water
level switch and the air
trap hose. Repair or replace
either as needed.
Does the machine continue
to fill with water?
NO
Is there voltage
from the terminal for the
water inlet valve that is allowing
water to fill the machine (i.e., CF,
HF, S1, S2 and S3) and
the ACN?
YES
Replace the output board.
Examine the water inlet valve
wiring. Repair/replace the wiring
as needed.