Troubleshooting
11. Contactor Analysis (FWD and REV)
Contactor Analysis (FWD and REV)
Is there voltage
(120 Volts AC) between the
FWD wire and the ACN?
Is there voltage (120 Volts AC)
between the REV wire and
the ACN?
3A
2A
1A
NO
Disconnect
power to the machine.
Using an ohm meter, is there continuity
between the coils on the KM3
contactor and the coils on
the KM4 contactor?
YES
Inspect the motor wiring and repair
or replace it as needed.
Inspect the motor and replace it
as needed.
YES
Replace the KM3 and/or the KM4
contactor(s) as needed.
NO
Manually operate
the KM3 and/or the KM4
contactor(s). Does the
motor function?
NO
Examine the wiring to terminal
strip 27. Repair and/or replace
the wiring as needed.
Replace the KM3 and/or the KM4
contactor(s) as needed.
YES
The contactor is not energizing.