Page view 27
26 F232203
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
5. No Supply Fill Analysis (OPL)
No Supply Fill Analysis (OPL)
With the machine beginning
a wash step that has been
programmed with a supply,
no water is coming into a
supply compartment.
3A
2A
Replace the supply fuse.
NO
YES
Is there voltage
(120 Volts AC) between
the supply terminal
(i.e., S1, S2 or S3)
and the ACN?
1A
2A
Replace the output board.
NO
Is there voltage
(120 Volts AC) between
the output side of the supply
fuse (i.e., S1, S2 or S3)
and the ACN?
Is there voltage
(120 Volts AC) between
the input side of the supply
fuse (i.e., S1, S2 or S3)
and the ACN?
YES
NO
3A
2A
YES