Troubleshooting
17. Compartment 2 of Supply Dispenser Not Flushing Completely
Dispenser Illustration
Compartment 2 of the
supply dispenser is not
flushing completely.
Is there low
water pressure
(i.e., less than 30
psi) to the supply
dispenser?
Cut a 3/4-inch by 1/2 inch notch out of the bottom of the
water deflector in compartment 2 of the supply dispenser.
Refer to the
Dispenser Illustration
.
NOTE: If the water pressure is corrected to factory
specifications, the notch must be plugged to avoid
splashing.
As an alternative, install a hose clamp onto one of the hoses
connecting to the top of the vacuum breaker and tighten the
hose clamp slightly. Refer to the Vacuum Breaker
Illustration.
NOTE: If the water pressure is corrected to factory
specifications, the hose clamp must be removed.