Installation
53
9002106
Steam Requirements
(Steam Heat Option Only)
For machines equipped with optional steam heat,
install piping in accordance with approved commercial
steam practices. Steam requirements are shown in
Table 7.
Never touch internal or external steam
pipes, connections, or components. These
surfaces can be extremely hot and will
cause severe burns. The steam must be
turned off and the pipe, connections, and
components allowed to cool before the
pipe can be touched.
SW014
WARNING
Steam Supply Information
18-75 100/135 165/200
Steam inlet connection, in (mm) 3/8 (10) 1/2 (13) 3/4 (19)
Number of steam inlets 1 1 1
Recommended pressure, psi (bar) 30 – 80 (2.0 – 5.5) 30 – 80 (2.0 – 5.5) 30 – 80 (2.0 – 5.5)
Maximum pressure, psi (bar) 80 (5.5) 80 (5.5) 80 (5.5)
Table 7