Fault Display and Troubleshooting Information
57
F232120
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
A-B 1305/A-B 1336
When the A-B 1305 and A-B 1336 drives encounter a
fault, an LED is illuminated. Refer to Figure 37 and
33, respectively. These LEDs are viewed with the front
cover removed. To view the specific fault description,
the HIM (parameter unit) must be installed. Refer to
HIM installation and operation.
Once the HIM is installed, the current fault condition
is displayed as shown below with the corresponding
fault code. Cross reference the number in Table 30 for
fault identification and possible corrective action.
In addition, A-B 1305 and A-B 1336 fault codes are
stored in a fault buffer with the capability to store up to
four fault codes. If more than four faults are identified,
the least recent fault is deleted to make room for the
additional fault. “Fault Buffer 0” is the most recent
fault. The faults are viewed using a HIM as shown
below. Refer to HIM installation and operation.
The fault parameters are identified as follows:
“Last Fault” Parameter #4 Most Recent
“Fault Buffer 0” Parameter #86 Most Recent
(same as
Parameter #4)
“Fault Buffer 1” Parameter #87
“Fault Buffer 2” Parameter #88
“Fault Buffer 3” Parameter #89 Least Recent
NOTE: FOR A-B 1336 ONLY. During normal
operating conditions (no faults present, drive
running) the fault contacts at TB2-13 & 14 are
open, and the contacts at TB2-14 & 15 are closed.
When a fault occurs, the state of these contacts will
change. On some machine models, this contact is
connected to a fault indicator light.
Serial Fault
F 10
Fault Buffer 0
48