Installation/Wiring
F232120
18
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Control Terminal Blocks
Description/Control Logic/Torque
Specifications
Control terminal functions are unique to each Allen-
Bradley Drive. Each drive’s control terminal is
addressed independently.
A-B 160 – Control Terminal Block (TB3)
Function
Input Mode Parameter
The control terminal functions are determined in part
by the Input Mode parameter #46. Changing this
parameter affects the function of some terminals. All
machines equipped with A-B 160 drives use Input
Mode “1”.
NOTE: If Input Mode is changed, power must be
cycled to the drive for the change to take effect.
Speed Selection
Motor speeds are controlled by solid state or relay
switch closure inputs to SW1, SW2, and SW3 in
conjunction with STR and STF (direction) inputs.
Refer to Figure 16 and Table 13.
Figure 16
A-B 160 Control Terminal Block Designations
Table 13
WARNING
To reduce risk of electric shock, severe
injury or death, allow machine power to
remain off for three minutes minimum prior
to working in and around AC drive. Proceed
with caution.
W662
CAUTION
The controller is supplied with an internal
power supply. Dry contacts or open
collectors are required for discrete control
inputs. If an external voltage is applied,
component failure could occur.
W663
Terminal
Number
Signal Machine Use
1, 3
SW1 Preset Speed Input #1
2, 3
SW2 Preset Speed Input #2
4, 3
SW3 Preset Speed Input #3
5, 3
STR Reverse Motion
6, 7
STF Forward Motion
8, 7
Stop Safety Device
9, 10
Programmable Output
1 Normally Closed
Not Used
10, 11
Programmable Output
1 Normally Open
Balance Output
PHM654N
Washer-Extractor
Control Hardware Drive Hardware
Solid State Switch
TB3
Input Mode = “1” Parameter #46
Typical Configuration
1 - SW1 - Preset Input 1
2 - SW2 - Preset Input 2
3 - Common
4 - SW3 - Preset Input 3
5 - STR - Start Reverse
6 - STF - Start Forward
7 - Common
8 - Stop
9 - Not Used
Detection
10,11 - Output - Balance
Jumper,*
Switch,
or Relay
* on older models