Installation/Wiring
F232120
16
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
A-B 1336
Input and output connections are performed through
terminal block TB1. Refer to Figures 13, 14 and 15.
Figure 13
A-B 1336
Power Block Terminal (TB1)
Table 7
A-B 1336
Torque Specifications
Table 8
GRD GRD R
(L1)
S
(L2)
T
(L3)
DC
+
DC
-
U
(T1)
V
(T2)
W
(T3)
To
Motor
To Motor
Protected AC Input
200-240V, 0.37 – 3.7 kW (0.5 – 5 HP) Terminal Designations
380-480V, 0.37 – 3.7 kW (7.5 – 10 HP) Terminal Designations
A1-A3 Frame
U083ME3A
DC
-
COM
BRK
-
Dynamic Brake
2
DC
Input Line
GRD GRD R
(L1)
S
(L2)
T
(L3)
DC
+
U
(T1)
V
(T2)
W
(T3)
To
Motor
To Motor
Protected
AC Input
380-480V, 5.5 – 7.5 kW (7.5 – 10 HP) Terminal Designations
A4 Frame
U084ME3A
Dynamic Brake
PE PE R
(L1)
S
(L2)
T
(L3)
DC
+
DC
-
U
(T1)
V
(T2)
W
(T3)
To
Motor
To Motor
Protected
AC Input
200-240V, 5.5 kW (7.5 HP) Terminal Designations
380-480V/500-600V, 5.5 – 11 kW (7.5 – 15 HP) Terminal Designations
B1 Frame
U085ME3A
B2 Frame
Dynamic Brake
To
Motor
To Motor
Protected
AC Input
PE PE R
(L1)
S
(L2)
T
(L3)
DC
+
DC
-
U
(T1)
V
(T2)
W
(T3)
200-240V, 7.5 – 11 kW (10 – 15 HP) Terminal Designations
380-480V, 15 – 22 kW (20 – 30 HP) Terminal Designations
U086ME3A
Terminal Description
PE Potential Earth Ground
R (L1), S (L2), T (L3) AC Line Input Terminals
+DC, -DC DC Bus Terminals
U (T1), V (T2), W (T3) Motor Connection
Drive
Frame
Size
Max./Min. Wire
Size*
mm
2
(AWG)
Maximum
Torque
N-m (lb.-in.)
A1-A4 5.3/0.8
(10/18)
1.81
(16)
B1 8.4/0.8
(8/18)
1.81
(16)
B2 13.3/0.5
(6/20)
1.70
(15)
*
Wire sizes given are maxium/minimum sizes that TB1 will accept