Programming
13
F232133
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Setting the Parameters
1. Locate the two buttons above and to the left of
the microprocessor. Refer to Figure 17.
2. Press and release both buttons at the same time to
enter PROGRAM Mode. The digital display will
show AtS.
3. Press either the left or right button until the
desired parameter is displayed. Refer to Table 4
to see parameters and their meanings.
4. Press and release both buttons at the same time
to display the setting for the selected parameter.
Press the left or right button to change the
parameter setting. When setting numerical
values, the right button increases the displayed
value and the left button decreases the
displayed value. Pressing and holding one of the
buttons causes the displayed value to change
more rapidly.
5. Once the desired parameter value is displayed,
press and release both buttons at the same time to
enter the new value.
6. To change another parameter setting, return to
step 3.
7. To return to RUN Mode, press the right or left
button until the digital display shows End.
Press and release both buttons at the same time.
The display will then either show a vend price or
alternately flash PAY and a vend price.
Programming Parameters
AtS Amount to Start Amount value required to start a single wash. Single coin: value must be evenly
divisible by the APC setting. Dual coin: value should be evenly divisible by both
Cn1 and Cn2 values.
APC Amount Per Coin Value of each coin inserted into the coin meter.
Cn1 Coin 1
(Dual coin only.)
Value of each coin inserted to the right slot of the coin meter (as viewed from the
front).
Cn2 Coin 2
(Dual coin only.)
Value of each coin inserted to the left slot of the coin meter (as viewed from the front).
ACC Accumulate How the display will show the start amount. Set to UP to display value of coins
inserted in the meter; set to Dn to display the difference between the value of the
inserted coins and the AtS.
FLS Flash Set to YES to have the display flash; set to no to have the display not flash.
Crd Credit
(Dual coin only.)
Determines whether or not overpayment by a customer is credited to the next wash. Set
to YES for the amount of overpayment to be credited to the next wash. The display
will show either a reduced vend price or the amount of overpayment, depending on the
setting of the ACC parameter; set to no for no credit given to overpayment.
Lot Lock-Out Time Determines the amount of time in seconds the coin counter board will pause when a
bad coin is inserted. When a bad coin is inserted, the display will read Err for this
amount of time.
Rot Relay-On Time
Ctr Counter Read-only parameter keeps track of the number of cycles the washer-extractor has
performed.
dPt Decimal Point Determines the position of the decimal point in the digital display. Set to 000 for no
decimal point; set to 001 for the decimal point to display on the right side of the
center digit; set to 002 to display on the left side of the center digit.
Table 4