Alliance Laundry Systems CHM166C Installation Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
Programming
9
F232133
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Setting the Jumpers Without Circuit
Board
NOTE: The following procedures must be
performed by a qualified electrician familiar
with the construction and operation of this type
of machinery.
1. Disconnect power to the machine.
2. Unlock and raise the top cover.
3. Remove the control module cover.
4. The mechanical timer is located in the middle of
the control module. The odd-numbered side of
the timer is used to change the duration of
individual cycle steps. Refer to Figure 2.
Eleven possible jumper configurations are
available for changing the cycle time. Refer to
Table 3.
Figure 2
1b 1 1a
3b 3 3a
5b 5 5a
7b 7 7a
9b 9 9a
11b 11 11a
13b 13 13a
15b 15 15a
17b 17 17a
19b 19 19a
Mechanical Timer Cycle Time Options
Jumper Setting PreWash Wash Rinse 1 Rinse 2 Rinse 3
Final
Spin
Cycle
Time
None 4 8 1.5 1.5 1.5 4 27.5
1a to 3a 4 4 1.5 1.5 1.5 4 23.5
1a to 3a to 3b -- 4 1.5 1.5 1.5 4 18.5
1a to 3a to 3b to 5b -- 4 1.5 1.5 1.5 2 16.5
1a to 3a to 5a* 2 4 1.5 1.5 1.5 4 21.5
1a to 3a to 5a to 5b 2 4 1.5 1.5 1.5 2 19.5
1a to 3b -- 8 1.5 1.5 1.5 4 22.5
1a to 3b to 5b -- 8 1.5 1.5 1.5 2 20.5
1a to 5a 2 8 1.5 1.5 1.5 4 25.5
1a to 5a to 5b 2 8 1.5 1.5 1.5 2 23.5
1a to 5b 4 8 1.5 1.5 1.5 2 25.5
*Factory Setting
Table 3