Alliance Laundry Systems Cabinet Hardmount SC80SN Service Manual Page 57

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 56
F232205 55
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting – B-Control Coin Models
17.The Control Stops in Mid-Cycle and Will Not Advance
Before beginning the troubleshooting, be sure that the IDC Harness Kit (Part No. F200189300 [all voltage
models except C-voltage] and F200189301 [C-voltage models]) has been installed onto the machine.
WARNING
When powering the machine down, allow time
(3 minutes) for the door lock capacitor to
discharge.
*
CHM455S
Is the basket
empty?
NO
START
Is
the drain valve
stuck or is there a
sluggish/backed-up
drain?
Repair/replace the drain
valve and/or clear the
drain from obstructions
as needed.
Recheck all wiring.
Make sure that the IDC
Harness Kit has been
installed onto the machine.
Is
the water supply
to the machine
turned on?
YES
Turn on the water
supply to the
machine.
NO
NO
Is
either the cold fill
(CF) or the hot fill
(HF) light on the
output board turned
on? See
Figure 17.
YES
Are
the water valve
fuses on the output
board blown? See
Figure 17.
Replace the fuses.
Replace the water level switch.
NO
NO
Is the basket
rotating?
NO
YES
YES
Is
there voltage
(220 Volts) on the
water valve
solenoid? See
Figure 18.
Repair/replace the
water valve and/or the
wiring to the water valve
as needed. Make sure
that the IDC Harness
Kit has been installed
onto the machine.
NO
Replace the water valve
solenoid and/or the
water valve.
YES
YES
NO
NO
YES
YES
C-voltage] and F200189301 [C-voltage models]) has been installed onto the machine.
Is
there voltage (220
Volts AC) from the
input terminal on the
3-second time delay to
the ACN1 tab on the
output board? See
Figures 8 and 13.
Repair/replace the
wiring from the ACH2
to the 3-second time
delay. Make sure that
the IDC Harness Kit
has been installed onto
the machine.
NO
Is
there voltage (220
Volts AC) from the
load terminal on the
3-second time delay to
the ACN1 tab on the
output board? See
Figure 8 and 13.
YES
Replace the
3-second time
delay.
NO
Repair/replace
the wiring to the
3-second time
delay. Make
sure that the
IDC Harness
Kit has been
installed onto
the machine.
YES
Is
the drain light
(DR) on the output
board on? See
Figure 17.
Repair/replace the wiring
from the water level switch
to the microprocessor.
Make sure that the IDC
Harness Kit has been
installed onto the machine.
YES
Is
the water
level switch
working
correctly?
Page view 56