Troubleshooting
2. No Cold Fill Analysis
No Cold Fill Analysis
1A
1A
2A
3A
3A
With the water turned on to
the machine, during a cycle
that has been programmed
for a cold fill, no cold water
is filling the machine.
If the
output board includes a fuse at
the CF location, test the CF fuse with
an OHM meter.
If the output board does not include a
fuse at the HF location, test the F20
and F21 fuses with an OHM meter.
Are any of the fuses blown?
NO
YES
Replace the blown fuse(s).
Remove the wires from solenoids
V2 and V10 on the cold water valve,
refer to the No Cold Fill Analysis
Dispenser Illustration. Start the
machine with a cycle that has been
programmed with a cold fill. Does the
F20 and/or the F21
fuse blow?
YES
NO
Inspect wire J22-1-12 V2.
Repair and/or replace the
wire as needed.
Reconnect
the wires to
solenoids V2 and V10 on
the cold water valve. Does
the machine fill with cold
water during a cycle that
has been programmed for
a cold fill?
NO
During a
cycle that has been programmed for a
cold fill, during the cycle's fill step, is the CF
light on?
If the output board includes a fuse at the CF
location, is there voltage (220 Volts AC)
between the CF and the ACN?
If the output board does not include a fuse at
the CF location, is there voltage (220 Volts AC)
between terminal J22-1-12
and the ACN?
NO
YES
Replace the output board.
NO
Is there
voltage (220 Volts
AC) between solenoid V2 on
the cold water valve and the
ACN and also between
solenoid V10 on the cold water
valve and the ACN? Refer to
the No Cold Fill Analysis
Dispenser Illustration.
YES
Replace the cold water valve.
4A
CHM371S