Troubleshooting
1. No Hot Fill Analysis
No Hot Fill Analysis
1A
1A
2A
3A
3A
With the water turned on to
the machine, during a cycle
that has been programmed
for a hot fill, no hot water is
filling the machine.
If the
output board includes a fuse at
the HF location, test the HF fuse with
an OHM meter.
If the output board does not include a
fuse at the HF location, test the F20
and F21 fuses with an OHM meter.
Are any of the fuses blown?
NO
YES
Replace the blown fuse(s).
Remove the wires from solenoids
V1 and V9 on the hot water valve,
refer to the No Hot Fill Analysis
Dispenser Illustration. Start the
machine with a cycle that has been
programmed with a hot fill. Does the
F20 and/or the F21
fuse blow?
YES
NO
Inspect wire J22-1-11 V1.
Repair and/or replace the
wire as needed.
Reconnect
the wires to
solenoids V1 and V9 on
the hot water valve. Does
the machine fill with hot
water during a cycle that
has been programmed for
a hot fill?
NO
During a
cycle that has been programmed for a
hot fill, during the cycle's fill step, is the HF
light on?
If the output board includes a fuse at the HF
location, is there voltage (220 Volts AC)
between the HF and the ACN?
If the output board does not include a fuse at
the HF location, is there voltage (220 Volts AC)
between terminal J22-1-11
and the ACN?
NO
YES
Replace the output board.
NO
Is there
voltage (220 Volts
AC) between solenoid V1 on
the hot water valve and the
ACN and also between
solenoid V9 on the hot water
valve and the ACN? Refer to
the No Hot Fill Analysis
Dispenser Illustration.
YES
Replace the hot water valve.
4A
CHM368S
2A