Alliance Laundry Systems 1336 Service Manual Page 94

  • Download
  • Add to my manuals
  • Print
  • Page
    / 95
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 93
94 F238006
Section 5 Service Procedures
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
Disconnect electrical power to the washer-extractor before servicing it.
Close the gas shut-off valve to the washer-extractor (when applicable) before servicing it.
Never start the washer-extractor with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W461R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
t. Torque the Front Bearing: Make sure that the
short 3mm Allen wrench is secured in the head
of the set screw. Alternately tighten the
mounting set screws in 1/2 turn increments
until they are tightened to 80in-lbs of torque.
The Allen wrench is designed to flex
approximately 3/4 inches when 80 in-lbs is
achieved.
u. Torque the Rear Bearing: Make sure that the
short 3mm Allen wrench is secured in the head
of the set screw. Alternately tighten the
mounting set screws in 1/2 turn increments
until they are tightened to 80in-lbs of torque.
The Allen wrench is designed to flex
approximately 3/4 inches when 80 in-lbs is
achieved.
v. Recheck each set screw and retighten them as
needed. No threads should be visible.
w. Check the up and down play of the basket. The
bearings are not correctly mounted if play
exists.
x. Apply methoxy sealant at the split of the
bearing sleeve.
NOTE: Make sure that the new cartridge seal has
0.125 inches of axial (spring pressure) movement in
it.
y. After the bearings are set, check to see if the
metal ring on the seal is against the nylon
retainer. If needed, slide the brass collar
forward until the ring comes into contact with
the nylon. This will set the correct seal spring
compression. Refer to Figure 35.
z. Tighten the brass collar to the shaft using the
three set screws located in the brass collar.
aa. Remove the retaining ring from the cartridge
seal using a screwdriver. Refer to Figure 35.
ab. Reinstall the pulley and the belt.
ac. Reinstall the door trim and shell band. Realign
them using the marks made in the previous step.
ad. Reinstall the door lock cover on the machine.
ae. Reconnect the spray rinse hose to the spray tube
assembly.
af. Reinstall all of the panels.
ag. Test the machine for leaks.
Figure 35
PHM277K
Retaining
Ring
Page view 93
1 2 ... 89 90 91 92 93 94 95

Comments to this Manuals

No comments