Maintenance
29
70380401 (EN)
Annual Maintenance
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumble dryer before servicing.
• Close gas shut-off valve to gas tumble dryer before servicing.
• Close steam valve to steam tumble dryer before servicing.
• Never start the tumble dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumble dryer is properly grounded.
W002R1
WARNING
Remove cylinder. Use a vacuum to
clean lint from area around rear
seal and idler assembly. Check seal
and idler assembly for wear.
Remove burner tubes and clean
using water and a brush.