Alliance Laundry Systems EAJ920*A Troubleshooting Guide Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 31
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
30
36528
Section 2
TROUBLESHOOTING
ELECTRIC DRYER
NO HEAT ANALYSIS
REPLACE INOPERATIVE
WIRING AT TERMINAL
BLOCK TO ELECTRONIC
CONTROL.
NO HEAT ANALYSIS
NO NO
DURING OPERATION AN "OP"
OR "SH" MAY BE DISPLAYED.
THIS INDICATES AN OPEN OR
SHORTED THERMISTOR.
USE DIAGNOSTIC TEST
"DRYER ON TEMPERATURE TEST".
IF "SH" OR "OP" APPEAR, DO
THE FOLLOWING CHECKS:
– CHECK WIRING AT THERMISTOR.
– REPLACE THERMISTOR.
NO
REPLACE LIMIT THERMOSTAT
AND THERMAL FUSE.
YES YES
DOES THE
THERMISTOR
TEMPERATURE
CHECK OUT ACCORDING
TO THE DIAGNOSTIC
TEST?
YES
(1) (2)
(3)
CHECK
VOLTAGE AT
PNK/BLK "FS–1"
TO "H4-3",
IS THERE
VOLTAGE?
CHECK
VOLTAGE AT
ELEMENT
ORANGE TO NEUTRAL,
IS THERE
VOLTAGE?
CHECK
VOLTAGE AT
ORANGE "FS–2"
TO "H4-3",
IS THERE
VOLTAGE?
AFTER CHECKING FOR CORRECT
WIRING, REPLACE INOPERATIVE
THERMISTOR.
REPLACE HEATING
ELEMENT.
REPLACE ELECTRONIC
CONTROL BOARD.
YES
NO
D214S
Page view 27