Installation
29
801546
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Exhaust System Maintenance
The dryer interior and the complete exhaust system
should be inspected after one year of use and cleaned
if necessary. Inspect and clean exhaust duct every one
to two years as required thereafter. The weather hood
should be checked frequently to make sure the
dampers move freely, dampers are not pushed in and
that nothing has been set against them. This
maintenance work should be done by a qualified
service person.
Exhausting the dryer in hard-to-reach locations can be
accomplished by installing the 521P3 Flexible Metal
Vent Kit, available as optional equipment at extra cost.
The kit comes in two halves that can be separately
attached to the dryer and wall outlet. Once attached,
the unit can be slid back into position.
Figure 29
Dryer Airflow
Efficient dryer operation requires proper dryer airflow.
Proper dryer airflow can be evaluated by measuring
the static pressure.
Static pressure in the dryers exhaust duct should be no
greater than that shown in Figure 30. (Check with
dryer running and no load.)
NOTE: This can be measured with a manometer
placed on the exhaust duct approximately 61 cm
(2 feet) from the dryer. Refer to Figure 30.
Figure 30
SWD647N
To reduce the risk of electric shock,
disconnect the electrical service to the dryer
before cleaning.
W043
WARNING
521P3 FLEXIBLE METAL VENT KIT
D012I
1 Manometer
2 Exhaust Duct
DR012A-IN
1
2
MAXIMUM STATIC
PRESSURE IN
WATER COLUMN
1.5 cm (0.6 in.)
MEASURING STATIC PRESSURE